燈具安規(guī)技術(shù)問(wèn)題匯總

1、EN 61347-1 附錄A1,A2,A3怎么測(cè)量?
2、什么是SELV等效控制器?--By Melodymg
3、現(xiàn)CB認(rèn)證的關(guān)鍵元器件清單中,很多工程師用IEC的標(biāo)準(zhǔn),這樣可以?
4、等離子燈具中,射頻驅(qū)動(dòng)模塊需要做測(cè)試嗎?或者需要有認(rèn)證碼?--By Yangcanluck
5、EN 61347-2-13中的Tc怎么找到?是不是表面每個(gè)位置的溫度都要測(cè)試過(guò),找到溫度最高的地方?--By Faige 2006
6、我司有一款臺(tái)燈,做UL 153,只有一根電源線加裝飾性的燈座。現(xiàn)在的問(wèn)題是:因燈座沒(méi)有與燈架充分固定,在旋轉(zhuǎn)燈座時(shí),電源線就會(huì)被隨著扭轉(zhuǎn),電源線扭轉(zhuǎn)會(huì)超過(guò)360度,有沒(méi)有標(biāo)準(zhǔn)條款可以免除固定燈座的要求?--By Kaiden
7、IEC/EN60598-1,60968中,輸入?yún)?shù)怎么確認(rèn)?例如:客戶標(biāo)稱100W,實(shí)際在額定電壓下只有60W,是否OK?
8、EN62031中過(guò)功率測(cè)試方法是怎樣的?--By arbi、Liyun_01
9、IEC/EN 61347-2-13中,SELV-equivalent是否已經(jīng)取消?
10、IEC/EN 61347-2-13中,接線端子是否需要評(píng)估60598中的8mm要求?
11、UL 1310+UL 8750的電源是否要求Class I電源的次級(jí)到地需要有Y-cap?--By浪子邊城
12、UL 1993+UL 8750對(duì)自鎮(zhèn)流球泡燈包裝要求(即標(biāo)示)?
13、UL 1993+UL 8750膠水老化測(cè)試要求?--By Ivy Chen
14、什么是general coverage?是專指免溫升測(cè)試嗎?
15、關(guān)于LED 臺(tái)燈等燈具,可以適用general coverage嗎?--By 無(wú)名氏
16、EN 61347電源驅(qū)動(dòng)產(chǎn)品只有壓線口沒(méi)有提供電源線,是否還要做60598的電源線拉力測(cè)試?--By 環(huán)日邊
17、12V MR16做CE是否一定要用Fuse?
18、保險(xiǎn)電阻會(huì)被限制使用嗎?
19、燈具做CE,對(duì)Fuse有什么要求?--By halphine
20、UL 1598中,天花燈,櫥柜燈做溫升測(cè)試時(shí)的設(shè)備是什么樣子的?--By elaincle
21、戶外景觀LED燈,驅(qū)動(dòng)電源板是否可以直接裝在金屬外殼內(nèi)?非隔離式電源是否可以先裝在塑膠管內(nèi)再裝入金屬外殼?--By yyh
22、哪些國(guó)家適用什么樣的燈頭可以從哪個(gè)標(biāo)準(zhǔn)上看到?--By 50366A1
23、溫升測(cè)試在常溫下測(cè)還是40度下測(cè)試?
24、溫升測(cè)試對(duì)于沒(méi)有標(biāo)出限值的器件怎么樣判定是否合格?例如:電源里的開(kāi)關(guān)IC、三極管、功率電阻等。
25、短路測(cè)試需要短路哪些器件?
26、爬電距離和電氣間隙不足,是否短路測(cè)試沒(méi)有安全隱患就能判定合格?--By Reliab
27、外殼為玻璃的球泡燈,輸出非SELV,這樣的結(jié)構(gòu)能否接受?
28、IEC 60598-2-20中對(duì)燈串marking的要求?
29、LED軟條燈測(cè)試標(biāo)準(zhǔn)可用EN60598-2-4或EN60598-2-20嗎?--By Ivy Chen
30、IEC60598-1中溫升測(cè)試的環(huán)境溫度是多少?25度還是規(guī)定的Ta(Max)?--By edwardguo 001
31、IEC61347標(biāo)準(zhǔn)中,怎樣區(qū)分獨(dú)立式鎮(zhèn)流器和內(nèi)置式鎮(zhèn)流器?--By Shalu 2
32、鎮(zhèn)流器內(nèi)部灌膠后,因?yàn)榻^緣要求已經(jīng)達(dá)到,可否不考慮爬電距離個(gè)電氣間隙的要求?--By jing 005213
33、EN標(biāo)準(zhǔn)和IEC標(biāo)準(zhǔn)的區(qū)別?EN 和IEC 標(biāo)準(zhǔn)偏差在哪里可以看到?
34、CB和LVD都指安全,他們的區(qū)別是什么?
35、GS和CE能等同嗎?還是要加上EMC?
36、Erp以及2013年1月2日Rohs的宣告?
37、是不是IT產(chǎn)品上所有的指示燈要做62471,Laser做60825?--By DavidFu,無(wú)名氏
38、LED路燈工作溫度定義為-40°--60°,驅(qū)動(dòng)電源是內(nèi)置的,做溫升時(shí)是以Ta值考量還是以Tc值做考量?
39、外置式獨(dú)立電源Ta與Tc的關(guān)系?
40、LED路燈要求IP等級(jí)大于IP65,如果能達(dá)到IP67,在標(biāo)簽上是否都要寫IP67,IP65?
41、LED路燈的整體是達(dá)到IP65,如果是內(nèi)置式電源,電源的防水等級(jí)如何考量?
42、LED路燈要求承受風(fēng)力測(cè)試,在認(rèn)證機(jī)構(gòu)測(cè)試時(shí),是以實(shí)際安裝角度來(lái)模擬測(cè)試還是認(rèn)證機(jī)構(gòu)自己定義?--By Babyliss
43、LED燈管做UL的標(biāo)準(zhǔn)有UL1993,UL8750,UL1598 ,是否出現(xiàn)標(biāo)準(zhǔn)重復(fù)?--By Kevin528
44、怎樣才能滿足UL2097?--By San zhu

 
6、我司有一款臺(tái)燈,做UL 153,只有一根電源線加裝飾性的燈座。現(xiàn)在的問(wèn)題是:因燈座沒(méi)有與燈架充分固定,在旋轉(zhuǎn)燈座時(shí),電源線就會(huì)被隨著扭轉(zhuǎn),電源線扭轉(zhuǎn)會(huì)超過(guò)360度,有沒(méi)有標(biāo)準(zhǔn)條款可以免除固定燈座的要求?--By Kaiden

答復(fù):
8.4 When wires pass through a joint between sections of a portable luminaire that are separable for packing purposes, the joint shall be such that rotation of one section with respect to the other during the assembly of the sections is limited to not more that 360 degrees. Friction alone does not meet the intent of the requirement to prevent rotation.
Exception: When all of the following conditions exist, rotation between sections of a portable luminaire is not limited to 360 degrees:
a) The internal diameter of the tubing through which the wires pass is 1/2 inch (12.7 mm) or more or the Power Supply Cord Twist Test, Section 135A is conducted with acceptable results; and
b) The rotation during assembly is limited to not more than one revolution for each 3 inches (76 mm) of unobstructed tubing length through which the wires pass, when such rotation does not place any stress on the conductors; and
c) The conductors do not involve splices unless the splices are:
1) Inaccessible during assembly in accordance with Accessibility of Live Parts, Section 23; and
2) Secured and provided with strain relief that has been shown to be reliable and not easily defeated by the user.

11、UL 1310+UL 8750的電源是否要求Class I電源的次級(jí)到地需要有Y-cap?--By浪子邊城
請(qǐng)看標(biāo)準(zhǔn):
UL1310:

12.2 There shall be no components connected between primary and output circuits which result in a conductive connection (see 5.4). If capacitive coupling is provided between primary and output circuits, it shall consist of either:

a) A capacitor complying with the antenna coupling requirements specified in the Standard for Capacitors and Suppressors for Radio- and Television-Type Appliances, UL 1414; or

b) Two capacitors connected in series, each capacitor complying with the requirements in 34.1.3.

UL8750:

7.9.2 A component that bridges two circuits otherwise required to be isolated from one another shall be one of the following:

a) A capacitor complying with the antenna coupling requirements specified in the Standard for Capacitors and Suppressors for Radio- and Television-Type Appliances, UL 1414,

b) Two capacitors connected in series, each capacitor individually complying with the dielectric voltage withstand test of 8.4,

c) An optical isolator complying with the requirements of the Standard for Optical Isolators, UL 1577, with a suitable isolation voltage rating, or

d) Isolation provided by a transformer that complies with the dielectric voltage withstand test of 8.4.

 

12、UL 1993+UL 8750對(duì)自鎮(zhèn)流球泡燈包裝要求(即標(biāo)示)?
必須看標(biāo)準(zhǔn),看結(jié)構(gòu), 不羅列。
13、UL 1993+UL 8750膠水老化測(cè)試要求?--By Ivy Chen
UL8750
6.7 Potting compound
6.7.1 Potting compound shall not leak, drip, or be released from a unit during any test conducted in accordance with this standard.
6.7.2 During the Temperature Test of 8.3, a potting compound shall comply with (a) or (b) as applicable:
a) A polymeric potting compound shall not exceed its Relative Thermal Index (RTI).
b) An asphalt potting compound shall remain at least 15°C (27°F) below its softening point as determined by the Standard Test Methods for Softening Point of Resins Derived from Naval Stores by Ring-and-Ball Apparatus, ASTM E28.

UL1993:
6.7.7 In the United States, when applying the requirements specified in UL 840 to determine environmental pollution, the device may be evaluated with different environmental pollution degrees. The following conditions apply:
a) A device marked for wet use shall be exposed to environmental pollution degree 3.
b) A device intended for dry or damp locations shall be exposed to environmental pollution degree 2.
c) The portion of a printed wiring board covered with a potting compound or a conformal coating that complies with the requirements in conformal-coating tests described in UL 746C shall be exposed to environmental pollution degree 1.
6.7.8 In Canada, printed circuit boards covered with potting compound or a conformal coating shall comply with the requirements of Annex E.

20、UL 1598中,天花燈,櫥柜燈做溫升測(cè)試時(shí)的設(shè)備是什么樣子的?--By elaincle
參考標(biāo)準(zhǔn)Clause 19.3~19.6.
43、LED燈管做UL的標(biāo)準(zhǔn)有UL1993,UL8750,UL1598 ,是否出現(xiàn)標(biāo)準(zhǔn)重復(fù)?--By Kevin528
回復(fù):有重疊也各有側(cè)重,各自均有考核重點(diǎn)。